Code reference · NEC 705.12(B)(3)(1)-(3); 705.28(A); 705.11
How much solar can you backfeed on a 150 A busbar with a 150 A main?
A 150 A busbar with a 150 A main breaker allows a maximum 30 A of backfed PV breaker under the 120% rule: 150 × 1.2 − 150 = 30 A (NEC 705.12(B)(3)(2)) — valid only when the PV breaker sits at the opposite end of the busbar from the main. The sum-of-supplies alternative (705.12(B)(3)(1)) allows nothing here, because the main already equals the busbar rating.
In inverter terms: a 30 A backfeed breaker supports up to 24 A of continuous inverter output (breaker ≥ 125% of continuous output, 705.28(A)) — about 5.76 kW at 240 V. Conductors for that output must be sized for at least 30 A.
If your inverter needs more than this panel allows: downsizing the main to the next standard rung (150 A → 125 A, 240.6(A)) raises the 120%-rule limit to 55 A — provided the calculated load still fits the smaller main; a supply-side tap (705.11) removes the busbar constraint but involves the utility side of the service; and 705.12(B)(3)(3) permits sum-of-branch-OCPDs sizing when an engineered study supports it. Rejections cluster on the opposite-end placement — inspectors check the physical breaker position, not just the math.
Run the numbers yourself
Need this as a permit-ready document?
One Document Credit ($29) buys a full clause-cited compliance PDF — wire sizing, voltage drop, overcurrent protection, every value traceable to the section it came from.
Get your document →Every numeric value on this page is computed by the CircuitProof calculation engine — the same golden-tested code that renders our permit documents — not typed by hand. Code text is paraphrased and cited; always verify against your jurisdiction's adopted edition and a licensed professional before installation. Design documentation, not a stamped drawing.
More references: How much solar can you backfeed on a 100 A busbar with a 100 A main? · How much solar can you backfeed on a 125 A busbar with a 100 A main? · How much solar can you backfeed on a 200 A busbar with a 200 A main? · How much solar can you backfeed on a 200 A busbar with a 175 A main? · How much solar can you backfeed on a 225 A busbar with a 200 A main? · How much solar can you backfeed on a 400 A busbar with a 400 A main? · all 97 references